Baxi EcoBlue System Boiler Error Codes
Attention: You can only go so far when it comes to DIY boiler maintenance. However, for a more rigorous inspection, with the right tools and expertise, you'll need to contact a professional. A Gas Safe Registered engineer will conduct a proper boiler maintenance check.
Possible Fault: Boiler temp reached
Action:
Possible Fault: Temporary Flame Loss (No Reset Required)
Action: Temporary error, self-reset, if continues will go to 3 red flashes (lockout).
Possible Fault: Communication Fault Between PCB And Control
Action: Temporary error, self-reset.
Possible Fault: Parameter Error On PSU/PCB
Action: Temporary error, self-reset.
Possible Fault: Miscellaneous Error
Action: Temporary error, self-reset.
Get an online fixed price in 20 seconds:
Q: What kind of fuel does your boiler use?
Possible Fault: Sensor Error: Sensor Fault, Temperature Fault Or Flow Fault
Action: Check The Wiring; Check That The Sensors Are 12kohms @ 25 degrees c ; Check That The Sensor is fitted into toe pocket; Check that the AAV is open; Check that the system is full of water and any air cleared; Check that the pump is running and that the flow and return is the right way round. Check for blockages in the system.
Possible Fault: Boiler Overheat Tripped
Action: Vent The Air In The Heating System; Check The Water Pressure; Check continuity across the overheat stat and that the A.P.S is operating (if fitted); Check The Circulation (Direction, Pump, Valves); Check The Wiring; Check System Pressure and That System Is Not Air-Locked.
Possible Fault: Ignition Fault. Boiler Has Failed To Light After 5 Attempts
Action: Check The Wiring; Check The Supply Pressure; Purge The Gas Supply To Remove Air; Check for spark at electrode; Check Ignition Electrode Condition and Clean/Replace If Necessary; Check Gas Valve is opening; Check Condensate Drain For Blockage.
Possible Fault: Fan Fault
Action: If fan is not running check for power to gas air unit; if the fan is running check A.P.S (if fitted) has operated. Check flue for blockages.
Possible Fault: Parameter Or PSU Error
Action: PCB And Condition Of Wiring Loom; Replace PSU And Recommission; Check The Wiring.
Possible Fault: Miscellaneous
Action: Check All Wiring Connections Are Correctly Made; If Necessary Replace PU And/or Control/Fan Assy.